Heisenberg IFO General
hudsonl - posted 10:44, Monday 07 October 2024 (11793)
MZI Lock with Analog Electronics
[Hudson, Melissa]

We switched the Mach-Zehnder interferometer's locking electronics from a red pitaya to analog electronics. This improved the RMS phase noise from about 250 mrad to about 9 mrad when locking with 2 uW of incident laser power on one interferometer input port. Above 0.5 Hz, the relevant low-frequency bound for our planned 2 second measurement(set by the red pitaya's memory and acquisition rate), the RMS phase noise is now 3.0 mrad. 

Assuming we decrease the power further by a factor of 4, we anticipate having roughly 12 mrad of RMS phase noise from the interferometer, which should still be low enough not to degrade squeezing substantially. The upshot is that we have experimental confirmation that there exists a CLF power level that is simultaneously high enough to lock the interferometer and low enough to allow us to measure high levels of squeezing. 

The measured 3 mrad of phase noise is also consistent with a theoretical model of the interferometer laid out in section VI.A of the attached document, which anticipates 0.8 mrad of RMS phase noise for an interferometer with phase noise suppressed to the shot + electronics noise level from 0 to 10 kHz.