Daniel, Wen
We received the Thorlabs 2x2 fiber switch last week and tested that it's working. Now that the CLF and LO paths are aligned to the fiber, we have pretty much everything we need to start working on the balanced homodyne detector.
The pump input to the cavity is re-aligned after testing the output PER of the green SM fiber. The polarization is still drifting, and we have bought green PM fibers to replace it. The seed beam is needed as a proxy of squeezed vacuum, but a coresonance condition will also induce strong nonlinear effect that we don't want to see. Back in LLO, we chose to dither-lock the VOPO cavity to have only seed on resonance. We currently don't have this digital control loop setup in LASTI.
Instead, we chose to detune the TEC such that the coresonance condition is achieved between fundamental mode of seed and higher-order mode of pump. Our OPO PDH signal has a high enough SNR to even lock VOPO on pump HOM resonances. Given about 1 mW of seed input, the VOPO transmission is around 15 uW, which turns out to be too small for the scanning-slit beam profiler. We tuned up the seed to have a transmission of 400 uW to measure the beam profile.
The LO SM fiber is not replaced with a PM fiber. The complex beam parameters of the LO output are also measured. Given these measurements, we have enough to design a homodyne path and try to get a very high visibility (~98%).
A few weeks ago, we took more time series data for Teraxion linearity measurements with higher frequency modulation amplitudes (2GHz and 5 GHz) and 1 kHz carrier frequency. The new data has been difficult to fit with both least squares and MCMC, but I recently tried using gradient descent for curve fitting and now have some informative fits for the 2 GHz data. These results required fitting for 10 harmonics, abandoning the assumption that all modes are in phase with each other, and adding a term for residual amplitude modulation. The results suggest that Teraxion is noticeably more non-linear for deeper frequency modulations (as opposed to 1 GHz that we fit for previously). I attach two fits and list their parameters below. fit27_10: V0: 0.6251 Vfringe: 0.7836 phi: 1.0711 a: 0.2020 (AM) psi_a: 3.0275 (phase of the AM) Modulation depths: m1: 0.7143 m2: 0.5826 m3: 0.5468 m4: 0.3856 m5: 0.2048 m6: 0.1631 m7: 0.0875 m8: 0.0747 m9: 0.0254 m10: 0.0266 Phases: psi1: 3.0520 psi2: 3.1502 psi3: 3.5166 psi4: 3.2619 psi5: 2.7604 psi6: 3.7823 psi7: 1.1881 psi8: 3.6516 psi9: 0.5109 psi10: 3.3111 fit28_10: V0: 0.2421 Vfringe: 1.4911 phi: 0.8916 a: 0.3625 psi_a: 3.2381 Modulation depths: m1: 0.6388 m2: 0.4169 m3: 0.4405 m4: 0.2875 m5: 0.1278 m6: 0.1349 m7: 0.0217 m8: 0.0379 m9: 0.0159 m10: 0.0089 Phases: psi1: 3.2005 psi2: 3.4836 psi3: 3.8031 psi4: 3.8273 psi5: 3.7472 psi6: 3.5363 psi7: 5.9480 psi8: 2.9835 psi9: 5.6154 psi10: 2.4806
Adding data files: 27, 28 - 2V; 29, 30, 33 - 5V
[Eric, Wen, Daniel]
In the LASTI squeezer setup, we have managed to resurect part of the LO-generation path. In this configuration, we want to generate the LO signal using two AOMs driven at the same frequency with frequency modulation on one of the two AOMs to allow for limitless tracking of the squeezing angle at the homodyne. Before we built the LO path out completely, we coupled the light from a single 80-MHz shifted signal following the first AOM into fiber and beat it against the CLF by combining them with a fiber beam splitter and shining the resulting combined signal on a New Focus 1611 RF photoreceiver. A simplified diagram of the experimental setup is here, along with a photograph of the setup here. In principle, this should allow us to analyze the spectrum of the CLF signal to see how nonlinearities/nonideealities of the AOMs in the CLF generation process behave.
Looking at the full heterodyne signal on an ESA here, we would ideally expect to see a tone only at omega3-(omega1-omega2) = 76.875 MHz. In reality, the spectrum is quite complex displaying a dominant heterodyne signat at 76.875 MHz and many undesired terms other frequencies. By removing the LO from the fiber beamsplitter, we can observe the CLF's "self" homodyne signal on the ESA here. This shows clear tones at both AOM drive frequencies (1 and 2), indicating that there must be some leakage of the seed "carrier" through the CLF path. The same can be done with just the pseudo-LO here, resulting in tones at the LO AOM3 drive frequency of 80 MHz, as well as some second-harmonic content.
In the next few comments, we will try to understand the sources of the non-idealities in the heterodyne spectra to see if we can pin down if/what AOM nonidealities are ultimately contributing to seeding of the OPO during normal operation.
We measured the CLF self homodyne today with RF drive to each AOM as:
AOM1 RF Drive Power: 30dBm
AOM2 RF Drive Power: 20dBm
The resulting CLF signal was measured on an RF PD (1611) and tones at the following frequencies were measured.
200 MHz: -63.7 dBm
203.125 MHz: -79.0 dBm
400 MHz: -59.6 dBm
406.250 MHz: -66.8 dBm
Futher analysis hopes to determine how much power there exists at the seed laser frequency from this data.
It might be useful to compare with this old post where I was debugging the original setup (the same AOMs and amplifiers, but different optical table with a different layout). I wasn't doing exactly the same thing, and it might be a bit tricky to compare numbers, but it gives an idea of the range of seed powers that it is possible to see with such a setup:
To access:
Username: reader password: readonly
I continued work on the VOPO alignment this evening. A couple hours with little progress, then I decided to translate the faceplate on M4 slightly since it didn't look like the mirror was perfectly centered when glued. After translating it up slightly I immediately saw some flashes. I just got the PD and camera set up in transmission so I can proceed with optimization tomorrow.
JD, Regina
COM Tests
We are trying to verify the center of mass of the top and UIM masses in an effort to place the wire break off points as close to d=0 as possible. We set up a single mass suspended by 2 wires and placed 2 displacement sensors on either end of the top of the mass (see figure 1). The entry on the old ilog describes the displacement sensor setup. In order to find the d-value, we measured the pitch motion and calculated the vertical offset based off the resonance. We kept the length of the wire the same.
We found that we need a resolution of 2 mHz to get to our target of measuring the d offset to 200 microns. We initially set the bandwidth to 512 s (0.002 Hz), but will probably do our next tests with 1024 s. We conducted experiments by changing the d-value of the wire by adding precision shims in between the clamp and the mass. Fig 3 shows the experimental results, and Fig 2 shows the modeled frequencies that we expect by fitting the values to match the longitudinal mode (higher frequency peak).
We had an idea of where the breakoff point should be compared to where the center of mass is, but we weren't not certain. We expected the d-value to be around 18mm above the COM, and we changed the value around to fit the resonances in the power spectrum. For this first run through, we didn't put the flags and balance masses on the mass which meant the COM is lower than what we expect it to be in the full setup. For the next setup, we'll try to recreate the full setup in more detail.
Cage
The parts for our cage around the masses came, and we began assembling it in the high bay. These parts allow us to align the masses precisely to one another and to the sensors. They also have space for us to add stoppers to hold the masses. Fig 4 shows the whole cage (we didn't put the brackets around the UIM yet). fig 5 shows a close up of one of the BOSEM holders we are testing out that has a kinematic coupling attachment.
Now that Slawek and Wen have repaired M4 and the Peltier, I was able to assemble and align the first VOPO spare cavity.
I had to do a bit of fixing on M4. The Piezo isn't perfectly centered on the aluminum mount and one of the leads was shorting to the faceplate. I scored the faceplate with a clean scalpel to create a small amount of clearance to eliminate the short. Now everything is fine. I also decided to swap the piezo leads with a pair of flexible wires from an old O3 mirror assembly.
I managed to route all the wires for the mirrors and oven without any incidents. Much easier with more flexible leads. I then proceeded to roughly align the cavity. I started by aligning the input beam through M1 and M2 so that the beam came out through the center of the holes in the lid. Then I aligned M1 s/t the reflected beam went through the output hole in the faceplate at the correct position. Finally i aligned M2-M4 s/t the beams hit all mirrors roughly in the center and the round trip beam overlapped with the input beam.
Next time I'm in I'll start scanning the cavity to begin the fine alignment process.
Since Rich would like to start testing C-6D, I summarise the current C-6D control strategy in this log and some known problems / solutions. C-6D would significantly gain from automatisation and from the LIGO Guardian. However, at the moment, most of the switching is done manually.
Procedure for ISI isolation with C-6D in loop: C-6D should be transitioned from the BOSEM control state (see the definition below) to the LPS control state. The transition happens by disabling inputs of CATCH RX, RY, and engaging FM1 on CATCH RZ filter bank, enabling inputs of DAMP RX, RY, RZ banks. Also, need to turn off outputs of CATCH X, Y, Z and engage outputs of DAMP X, Y, Z. No need to clear history in any of these steps. Now ISI controls can be enabled.
Procedure for disabling ISI isolation with C-6D in loop: C-6D should be transitioned from the LPS control state to the BOSEM control state. Disable inputs of DAMP RX,RY,RZ and engage inputs of CATCH RX, RY and disable FM1 of CATCH RZ. Then disable outputs of DAMP X, Y, Z and engage outputs of CATCH X, Y, Z.
BOSEM control state: this is the usual C-6D state when it is not in loop. The inertial mass is damped in X,Y,Z and caught in RX, RY, RZ with a bandwidth of 15 mHz. This state is quite robust and should survive ISI trips and earthquakes without losing the mass out of the sensor range.
LPS state: this is the usual C-6D state when it is in loop. The state is a bit more fragile than the C-6D BOSEM control state but it is lower noise and has proper dynamics. RX and RY are controlled with a bandwidth of 1 mHz + its resonances at 8 mHz and 16 mHz are damped to Q of 2.85 - 3.
Known minor challenges during the transition (occur frequently, easy to fix, and should probably be a part of the automatisation script):
LPS signals are large: If C-6D is caught with BOSEMs, such that RX = 0 um, RY = 0 um, and RZ = -300 um (see um column in the “BOSEM SIGNALS” block of the SIXD master MEDM screen) but LPS signals are more than a few um (see um column in the “LPS SIGNALS” block of the SIXD master MEDM screen) then LPS should be reset. This scenario typically occurs when ISI trips and LPS sensors accumulate junk signal due to fast oscillations of the inertial mass. It is fine to reset LPS during every transition because it is quick. Go to the LPS MAIN window and click 6 buttons V1, V2, V3, H1, H2, H3 RESET in the “Linearisation” block.
Signals in the DoF DECOUPLING block are large (nm column): if LPS signals were large and then reset (as discussed in the previous step) then these large signals may decay for a while in three slow filters: two feedforward filters (X/RY and Y/RX) and one matching filter (to equalise the response of RX and RY to the platform tilt). If the signals in the nm column are more than 20,000 nm, it is worth clearing the history of these three signals. Go to the FF window and then clear history in filter banks 5_1 and 4_2. Then go to C-6D RXYZ window (also inside the DoF DECOUPLING block) and clear the history of the FF_SENS_RY filter bank.
Known major challenges (some are easy to fix and some items require time to fix):
C-6D loses balance (and cannot be caught again with the coils) if ISI is controlled with GS-13 [fixed]: this occurred once (log 11906) because the C-6D 5.8 Hz bounce mode (with a large Q-factor) couples into the ISI dynamics. The ISI has strongly excited the mode (by a few mm) and unclamped masses (such as balancing magnetobullets) moved on the mass. This problem is addressed by engaging the CATCH Z damping servo as discussed above if C-6D is not in loop. Once this occurred, Rich and I have rebalanced the mass with magnetobullets.
C-6D loses balance if ISI is tripped with C-6D in loop: this happens frequently because LPS accumulate junk once they measure fast signals. Therefore, C-6D should transition from LPS control to the BOSEM control as soon as possible. If done within a few sec, C-6D should not loose balance. However, since we do not have Guardian at the moment, and ISI may trip when no one is looking, junk LPS signal imbalances C-6D. In this case, it is required to transition C-6D to a slightly altered BOSEM control state: X, Y, Z are as usual (unless the C-6D motion is so large that CATCH gains for X, Y, Z should be lowered a bit to avoid the actuator saturations). CATCH RZ is in its usual state. CATCH RX, RY should run with FM6 engaged instead of FM1 ('damp' instead of 'catch'). The mass is typically parked in the state with BOSEM RZ of -650 um. The RZ servo will slowly bring the mass back. It might take time. It is feasible to help the servo by adding a negative offset (of -1000) to H1 COIL with a ramp of 30 sec. The offset must be removed immediately once the inertial mass starts to move (BOSEM RZ signal grows). Then the servo should catch it (potentially after bouncing back and forth between the rails for a couple of times). Once RZ is caught at -300 um then ramp down the gain of CATCH RX and RY, switch off FM 1 (damp), switch on FM1 (catch) and then slowly ramp the gain to -1 (with a ramping time of 60 sec).
C-6D centre of mass sagging: this occurs due to a compressive load of Epo-Tek 353 ND between the C-6D mass and the spacers between the mass and the fused silica anchor. We tried to minimise the layer thickness by heating both surfaces to 100 C (to improve the 353 ND's viscosity) but there is still a bit of sagging. In the long term, this should be fixed by cutting a monolithic fused silica mass with spacers. The sagging is very slow. So far, I had to reduce C-6D feedforward and RX/RY alignment filters twice (in 2.5 months and 5 months after installation). During the first 2.5 months, epoxy sagged by 203 nm and during the last 2.5 months - by 61 nm. The consequence of this sagging (and this is how it is estimated) is that the tilt modes increase in frequencies: from 7.4 mHz to 8.15 mHz during the first 2.5 months and from 8.15 mHz to 8.35 mHz. This change requires retuning of the X/RY and Y/RX feedforward filters and RX/RY coalignment filters. Since 353 ND's sagging slows down, I expect the next retuning might be required in ~half a year or longer. The problem can be diagnosed if RX and RY blends start to ring at around 8 mHz. Then, it is required to transition C-6D to the LPS control state and slightly excite RX and then RY degrees of freedom and measure the damped period and Q-factor (should be around 3).
C-6D drift: sagging of Epo-Tek 353 ND also leads to drift in the C-6D. It seems like a small effect though and we did not have to correct it yet. However, this might happen in the future. If DC vertical coil signal are large than ~14,000 cnts, it might be a good time to rebalance C-6D with magnetoguns.
C-6D LPS nonlinearities: this is quite an interesting challenge that we did not see before. During the past two months, the LPS laser current modulation reduced by 10%. The cause is unknown but most likely the modulation of the index of refraction of the DFB cavity is temperature dependent. Since we do not have a temperature controller for the DFB laser at the moment (though it might be very good to have one, such as Thorlabs TED200C), the DFB modulation has reduced. The consequence of this change was quite interesting: when engaging ISI loops with C-6D in loop then Z, RX, RY, and RZ engage fine but X rings at 1.7 Hz (looks like ISI eigen mode) and trips the ISI. This is probably how non-linear control systems work; I think quite counter-intuitive. To fix this problem, we need to control the DFB temperature and (once it occurs) linearise LPS. This can be done by providing 10 um offsets to CATCH RX, RY, RZ loops (such that the mass moves by a few fringes) and recording 10-30 sec of LPS COS and SIN signals. It is typically sufficient just to balance the amplitudes of the two harmonics. A more details Matlab script linearise_LPS.m is in Documents/birmingham. Note that it returns the ellipse rotation angle (should be inserted with a minus sign to the MEDM LPS ROT field inside the "Linearisation" block. The script also returns 'ratio' which is the gain for relevant COS quadrature.
LPS demodulate phase correction: the phase typically stays stable. However, I noticed (both in Birmingham and MIT) that the phases have to be adjusted after CDS reboot. I think real-time oscillators at different frequencies end up at random phases between each other after reboots. The demodulation phases should then be corrected. Note that the phase error column should show numbers around +/- 90 degrees because we proceed with the Q-quadrate. Correcting the phase is quite straightforward. However, LPS signals might change their signs after this correction. The sign should be validated against BOSEM signals. Provide an offset to CATCH RX servo and observe how signals in BOSEM SIGNAL and LPS SIGNAL (um column) change. If the direction is the same then the problem is fixed. Otherwise, need to flip LPS signs in LPS XYZ, RXYZ filter banks (within LPS SIGNAL block).
Below, I also summarise the C6D master MEDM screen and control strategy:
BOSEM path: BOSEM V1-3 and H1-3 filters apply dewhitening and calibrate BOSEM signals to um. The DIAG matrix converts BOSEM signals to XYZ, RXYZ at the local coordinate system (defined by the RX,RY diagonalisation). These signals then go to CATCH filter banks and then to COIL XYZ, RXYZ. These control signals are then converted to the H1-3 and V1-3 COIL basis with ACT matrix. Note this is still in the local C-6D coordinate system.
LPS path: LPS V1-3 and H1-3 apply calibration from the Lissajous phase to um. Then matrix DIAG converts the signal to XYZ, RXYZ in the local C-6D basis. These signal go to DAMP XYZ, RXYZ to control C-6D in the low noise regime. Note that the name "DAMP" stays there for historical reasons and must be replaced in the future. LPS signals do not only damp but also catch the mass in RXYZ.
DoF DECOUPLING path: LPS signals (not BOSEM signal) flow to the FF block where X/RY and Y/RX feedforward is applied to diagonalise the degrees of freedom. Then C-6D XYZ, RXYZ filter banks calibrate the signals to nm or nrad and also apply a frequency-dependent filter to RY (to equalise its response to RX in tilt). This step is required due to the asymmetric fibre. The nm column means nm signals in XYZ and nrad signals in RXYZ.
COORD ROTATION: Matrix TO CARD rotates the signal from the C-6D system to the ISI coordinate system (by 30 degrees). ISI XYZ and RXYZ filter banks apply correction gains (on the order of 1) to match the C-6D signals to GS-13 signals in the frequency band around 0.5 - 5 Hz.
TEMPERATURE block: just monitors T around C-6D and shows signals in K relative to 25 C. Typically around -10 K (15 C) but may change quite a bit (up to 5 degrees) when weather in Boston changes.
MAGNETOGUNS block: rebalances the mass (once needed). Only the second channel is utilised. Frequency should be 3.8 kHz (corresponding to the gun's LC circuit resonance). Amplitude can be around 15,000 - 33,000 cnts and duration around 30 - 300 cycles. Higher amplitudes and longer duration of the pulse move the mass longer (quadratically in the number of cycles).
ISI control sequence with the C-6D in loop:
Null CPS signals and engage Z with GS-13 in loop (CPS and GS-13 blending filters: 100). Then slowly ramp (in ~5 sec) the C-6D Z blending signal (with FM1 R5.8 engaged). This should help damp the C-6D bounce mode. This is the only C-6D signal that should be ramped. Note that the Z isolation loop will likely not engage if the C-6D signal is blended during the ISO gain ramping and may strongly ring up the C-6D bounce mode. All other C-6D blend signals should be engaged from the start.
Then engage RX,RY,RZ isolation loops with CPS/C-6D blending at 25 mHz and C-6D / GS blending at 2 Hz. The blending filters are likely to change. At the moment, they are as follows. CPS RX, RY: 25m_B and CPS RZ: 25m. C-6D RX, RY: 25m_B + LP2b + LP20 and C-6D RZ: 25m + LP2b + LP20. GS13 RX, RY, RZ: 250 + HP2.
Once the transient from RX/RY has passed (within a minute or two) then engage XY isolation loops. The blending filter are as follows. CPS X,Y: 35m_B. C-6D X, Y: 35m_B + LP2b + LP20. GS-13 X, Y: 250 + hp2.
I switched the MZI lock over from using an LB1005 to a Red Pitaya. We decided to make this switch since locking the MZI exactly at mid-fringe seems critical to saturating the waveform quantum Cramer-Rao bound, and a computer is better suited to this task than a person looking at a scope. The fundamental issue is that the MZI error signal is small, and there are DC offsets on the differential receiver's output, the LB1005, amplifiers, etc. The feedback loop is now differential receiver -> SR560 (50x non-inverting gain) -> Red Pitaya -> PZT amplifier -> MZI PZT In contrast to the setup's previous configuration, there is no analog amplifier between the red pitaya's output and the PZT amp. Similarly, we added the SR560. Both of these were done to minimize effects of digitization in the RP's inputs and outputs. The red pitaya curve fits the differential receiver's output vs PZT drive signal to determine the setpoint corresponding to mid-fringe (this assumes the signals on the differential receiver are balanced, which should be verified before running the experiment). This is then the setpoint of the PID loop. We can achieve lock bandwidths of up to 5-10 kHz, but want to restrict the bandwidth to be less than 1 kHz so the 8 kHz modulation tone is much greater than the UGF and is not suppressed. From the transfer function, we see that the PZT mirror assembly has a structural resonance at about 700 Hz and a PZT resonance at about 25 kHz. The script seems to acquire lock consistently and stays locked for >15 minutes.
Lisa, Rich
Once a year Elizabeth from Caltech asks me and RIch to verify some piece of equipment in LASTI.
A tricky one to find is this one: Property tag: C21842
https://services2.ligo-la.caltech.edu/Inventory/history.php?recid=7&invtype=mit_federal
which I have now identified as being in the racks near the 16m tube, pictures attached.
Now we know, and we will never forget.
Swadha, Evan
Having locked a 1064 nm laser to the TIR cavity in the p polarization, we measured the control noise, the open-loop gain, and thereby made an estimate of the freerunning noise (attached).
Again by driving phase sidebands with the EOM and then sweeping the drive voltage into the laser driver, we measured a calibration of the control signal of 59 MHz / V. There was some drift in the laser power (partially due to having to tune the temperature to keep the laser near the 00 mode), so there is some uncertainty in this calibration.
Currently the UGF is about 60 kHz, using an SR560 with a dc gain of 6 dB and a pole at 3 kHz, then an LB1005 with an ac gain of −4 dB and a PI (boost) corner of 3 kHz. To reach the thermorefractive noise at 100 Hz with this laser would require a loop gain of 100 dB (currently 60 dB). That is probably doable with a few boosts at 10 kHz, and maybe some compensation to bring the UGF up to 100 kHz. It also becomes easier if we used an NPRO (though then with the complication of more free-space optics), or if we switched to a 1550 nm Planex, which has an order of magnitude lower noise.
The bulk thermorefractive noise is just taken from the gwinc calculation, which assumes a planar two-bounce FP geometry. We'll probably need to resurrect Deep's Comsol models for an exact computation.
[Jasper] To get an idea of the frequency noise of the Toptica CTL with and without the NKT Boostik I used the unequal arm length fiber Mach-Zehnder interferometer I put together a while ago, which has an arm length difference of 10m. The interferometer sits inside a metal box that is padded with rubber sheets and acoustic foam. Only the input and two output fibers are coming outside the box and I tried to seal to opening for the fibers as best I can with small rubber pieces. I put a fiber attenuator in the input of the interferometer to adjust the input power. The output fibers are connected to two fixed gain Thorlabs InGaAs PDs. The idea of the measurement is to lock the interferometer at midfringe and use the differential output signal as a frequency readout. Although the two PDs are the same model and new, one of them was significantly less sensitive for some reason, i.e., the output voltage was only about 80% compared to the other one for the same incident power. I want to look into this again, however, as it seems to work fine otherwise I simple attenuated the other PD signal with a voltage divider to balance the outputs. In the configuration that I ended up using the maximum power in the outputs was about 1.2mW (measured with a power meter) corresponding to 7.3V on the PDs (measured with a 1MOhm impedance oscilloscope) (exact values commented in the measurement files on the Dropbox). To lock the interferometer at midfringe I used a Newport LB1005 servo controller to feed the differential signal back to the piezo voltage of the CTL. Setting up the lock was a bit tricky a since there was only a small margin where the gain was large enough to keep the interferometer at midfringe without ringing due to a resonance in the actuator transfer function at 3.8kHz. Eventually I found a configuration where the interferometer stayed locked for at least 10min at a time, which was more than I needed and is only a lower bound given that I did not test it for longer. In this configuration the unity gain frequency was around 100Hz (measured with swept sine with SRS785). The exact control bandwidth does not matter, only the fact that it is significantly below the measurement band (1kHz to 10MHz), as I am measuring the frequency noise in the error point of the midfringe lock loop. The power spectral density at the error point was measured with the HP4195A (50 Ohms input impedance). I performed the measurement for the CTL directly, and for the laser amplified with the Boostik at the lowest and highest gain setting, i.e., 200mW and 2W nominal output power respectively. I also measured the error point dark noise with the loop off and no light in the interferometer. The result can be found below. The frequency noise measured for all three configurations is identical. This indicates that the amplifier has no impact on the frequency noise, which would be great news. It is also possible, that some other, common noise is limiting the measurement. The noise floor of the interferometer is unknown, however, when I performed tests with the NKT Adjustik I measured a noise performance below this level, so I think this is unlikely. Furthermore, the noise floor of around 10Hz/rtHz above 100kHz would fit well to the manufacturer specification of an instantaneous linewidth of 300Hz (see also: https://www.toptica.com/fileadmin/Editors_English/04_applications/10_application_notes/05_Linewidth_Measurement_of_Diode_Lasers/Linewidth-measurements-of-diode-lasers.pdf). Regardless this gives us an upper bound on the noise performance in the MHz regime which is quite promising. I still want to investigate this further for example by repeating this measurement with the NKT Adjustik. I also would like to perform a beat measurement of the CTL with the Adjustik to independently verify the measurement.
[Wen, Eric, Daniel]
Today, we finished realigning and mode-matching the CLF beam on the out-of-vac table in LASTI. The ideal thin-lens mode-matching solution from alamode is attached here given the available 300-mm and 88.3-mm focal-length lenses. In practice, the position of lens 2 needed significant adjustment to achieve good mode matching (see image/diagram of completed setup). The origin of this discrepancy is unclear, although it could be explained by a mislabeled lens. The rest of the lens/collimator positions were close to the thin-lens solution. The final positions of all components in the chain are given in the setup diagram.
Something else that through me through a loop was that I was struggling to walk the beam into the center of the collimator using combinations of M2, M3, and M4. This was preventing us from achieving a coupling efficiency above 50%. Eric thankfully pointed out that the Gouy-phase separation between these three mirrors was too small and that their actions would be degenerate (in this case they could only really affect the incidence angle of the beam on the collimator). Switching to using M1 and M4 to course walk the beam and then using M2 and M4 to achieve fine alignment allowed us to achieve a coupling efficiency of 95% fairly easily. With 9.99 mW of CLF incident on the collimator, 9.50 mW was measured at the other end of a standard single-mode fiber. Following this, flippers for both the seed path and CLF path were reinstalled and are also working nicely.
[Jasper] I successfully installed the Toptica CTL as the low-power, tunable seed laser and the NKT Boostik as the high-power amplifier. The CTL is tunable from from 1510nm to 1630nm, with a maximum output power of ~30mW at 1560nm, i.e., the nominal wavelength of the experiment. The NKT Boostik is an erbium-doped fiber amplifier, which nominally provides up to 2W of output power in the frequency range from 1545nm to 1565nm. I measured the power with a fibercoupled powermeter downstream of a fiber isolator in the 10% output port of a 10:90 fiber beamsplitter, which gave up to 150mW at maximal gain of the Boostik. Taking into account the manufacturer provided insertion losses this corresponds to 1.84W out of the amplifier and 1.68W behind the isolator. The Boostik test certificate of the manufacturer gives no specification of the exact output power. One stability plot suggest that it should be around 1.95W (however, it is not clear how this measurement was performed or calibrated). This would correspond to 110mW losses, i.e., 5.6% or 0.25dB, that are not accounted for. I lack the experience to gauge if this discrepancy is within the expected margin or if this points to real, extraneous losses. Further investigation might be necessary at some point. Regardless, I continued to perform some RIN measurements. For this I implemented a variable optical attenuator in the measurement port and connected it to a fibercoupled PD. I measured the RIN for different nominal output powers of the Boostik, and always adjusted the power incident on the PD to 2mW, corresponding to a DC voltage of 3.3V measured with an oscilloscope (1MOhm impedance). The responsivity of the PDs is specified by the manufacturer as 1.04A/W at 1550nm, which corresponds to a quantum efficiency of 82.7%. To measure the RIN I used the HP4195A from the e-workshop (50 Ohms input impedance). To high-pass filter the signal to avoid saturation of the input range from the DC component, I put a 10uF capacitor in the input of the HP4195A, which together with the input impedance should result in a corner frequency of about 320Hz. I then measured the RIN at 200mW, 500mW, 1W and 2W nominal output power of the Boostik (always adjusted to the same DC level on the PD with the attenuator). I also measured the PD dark noise and HP4195A noise floor. Lastly, I repeated the RIN measurement for the CTL without amplification to compare to the results from the demo unit a couple of months ago. For this I operated the CTL at maximal diode current (300mA), i.e., around 30mW output power, and attenuated the beam on the PD to 2mW as for the other measurements. The plots are found below. The RIN measurement for just the CTL is close to the electronic noise floor except for some features in the kHz range, especially the 3.8kHz peak. These kHz features also appear in frequency noise measurements with the fiber interferometer and are sensitive to vibrations, so I assume they are an internal mechanical resonance of the laser head, probably of the piezo or grating assembly. Accounting for the electronic noise, the measurement suggests that the CTL is shot noise limited for the detected power above 10kHz. The measurements with the Boostik agree for all gains above 5kHz and match the CTL noise above around 200kHz. In other words even after the amplifier the laser remains shot noise limited at high frequencies. Interestingly the low-frequency noise appears to improve roughly linearly with the gain/output power. This behavior makes me think that this might be some internal feedback stabilization which has a better signal-to-sensor-noise ratio with higher powers. This is outside of our frequencies of interest, but it is convenient. Overall, these are very nice results, as this means we hit our RIN target in the MHz frequencies without any additional stabilization.
Evan, Swadha
We had previously coupled the input and output prisms to the cavity using copper foil of estimated thickness ~1um, which gave us a cavity finesse of 76. We now switched to Aluminium foil of estimated thickness ~1.8um. We expected lower transmission coupling and thus higher finesse, which we achieved.
Switching the output coupling:
We started by switching the output prism coupling to Aluminium, and unscrewing the input prism to increase gap size for higher finesse. We re-aligned slightly to recover the TEM00 mode. Measured data:
1. In p-polarization: finesse = 1064
2. In s-polarization: finesse = 3500
However, with the input prism unscrewed, the setup was no longer stable and very sensitive to vibrations.
Switching the input coupling:
We then also changed the input prism coupling to Aluminium, and re-aligned. Measured data:
1. In p-polarization: finesse = 833 (TEM00 mode here, mode structure here).
2. In s-polarization: finesse = 1820 (TEM00 mode here)
3. Cavity p-s splitting = 73.4 MHz (data here)
We were able to lock the cavity in both polarizations.
Attachments show expected cavity coupling properties assuming 1 nm rms microroughness on the internal faces, a bulk absorption of 5 ppm/cm, and equal input and output transmission values. This is the basis on which we infer the copper leaf was slightly more than 1.0 µm in situ (previously, we had estimated 0.6 µm by folding a square of leaf four times and measuring with a micrometer). It is the basis on which we infer the 1.8 µm aluminum microphone foil is perhaps more like 2.2 µm in situ. It could be creasing, although visually the foil looks quite flat when viewing the interfaces.
We had to crank somewhat hard on the front setscrew to achieve what we think is something close to critical coupling in p (it seemed to be very undercoupled before). The mode matching is still quite poor, so inferring anything quantitative about mode matching right now is difficult.
The attached sympy script computes the transverse mode spacings (92 MHz tangential, 65 MHz sagittal), and the expected waist radii (0.41 mm tangential, 0.48 mm sagittal at 1064 nm), assuming nominal cavity parameters (side length 5.08 cm, ROCs both 5.0 m). I think we missed a factor of 2 earlier and the FSR is in fact 1.44 GHz. The previously stated finesse values need to be divided by 2. In that case, the inferred leaf thicknesses are something like 0.7–0.8 µm for copper and 2.0 µm for the microphone foil — so some 0.2 µm of excess or so (perhaps still creasing, but less than we thought).
Looking at the camera, the nearly co-resonant mode that we observe is some TEM(0,n) with n of order 20. Indeed, taking the FSR divided by the tangential TMS indicates we should expect the TEM(0,22) mode about 1.3 MHz below the 00 mode. Instead, we see the co-resonant mode at about 2.0 MHz below, which could be consistent with the TEM(0,22) if the curved faces are about 0.1% more planar than 5.0 m.
I am also attaching an archive of the raw oscilloscope data for the above plots. The file numbering is
The calibration was done by driving the EOM while sweeping the laser current. A 49.2 MHz drive produces sidebands in transmission corresponding to 1.44 V of input to the laser driver, hence 34 MHz/V. The thermistor readback was 7.27 kΩ, and the current knobs were 6′00″ coarse and 7′30″ fine.
Daniel, Wen
As mentioned in our previous log11934, we saw two close-by resonant peaks in the cavity with the same 00-mode shape. They are the separate resonances of s-pol and p-pol in a bowtie cavity. The best crystal spot in log11947 is also likely at the temperature where s-pol and p-pol peaks overlap, as observed while we sweep the cavity as well as the TEC. We would want to send a purely s-pol pump to the VOPO.
We tested the in-vac polarizer and HWP first on the old FCG path. The extinction ratio of the transmitted beam through the PBS before the FCG AOM was not great. We put a QWP before the FCG pickoff PBS to correct the elliptical pol. With the HWP before PBS, we could observe an extinction of 35 mW/2.4uW ~ 15000. We then replaced the in-air HWP and PBS with the in-vac optics for testing. We obtained an extinction ratio of 34.7 mW/5.7 uW ~ 6000, proving that the in-vac optics are correctly specified.
Putting back the optics in-vac, we examined the output of the pump fiber by measuring the polarization. We reversed the order by putting HWP before the polarizer. After adjusting the input QWP and HWP pump fiber launch and in-vac HWP, we measured the extinction ratio of 0.93 mW/1 uW ~ 930, which is roughly equal to the designed pol isolation of 1000. However, plucking the pump fiber easily reduced the extinction ratio to less than 100, as the pump fiber is not polarization maintaining. It's also not an alignment problem because the fiber output power measured before HWP and polarizer is very stable (as stable as a fluctuating level of 0.01 mW of total 3.73 mW output). If we don't touch the fiber, the extinction ratio drifts to about 5 mW/20 uW = 250 at an interval of minutes.
Yesterday we re-organized the 10-m fibers and loosed their strain. We moved the fiber to the far side of the SQZ table where there's less human activities. We covered the fiber feedthrough with plastic bubble wraps and secured them better than before. We walked the waveplates and left the extinction to be ~1000 before leaving last night (QWP was 60 deg, and HWP was 310 deg).
Daniel checked this afternoon, and the extinction again drifted badly to 3.82 mW/0.182 mW ~ 20. Daniel recovered it and then let it sit there. Around 2 hours later, the powers were 3.46 mW/0.486 mW ~ 7. We are planning to install a rigid tube covering the fibers and see if it improves polarization stability. PM fibers would be worth trying and would be critical for LO in the future.
Swadha, Evan
We had struggled for a while to align into the cavity by coupling in reflection with a single prism only, and with the entire cavity mounted vertically (letting gravity set the kinematic contact between the prism and three small squares of copper leaf). The key changes this time were to mount the cavity horizontally (with kinematic contact described below) and to couple with two prisms (one input one output) so that transmission information is available for alignment.
The key points of the optical setup were:
The optical alignment procedure went like this:
Our estimate of the finesse in s is based on the following:
The key points for future iterations of this procedure are as follows:
Attachments show the optical layout, and CCD videos of the p and s polarized transmissions as the laser frequency is swept.
Matt, Swadha, Evan
We were able to PDH lock the cavity with a bandwidth of about 20 kHz. In the kilohertz range the driver and the laser current actuation have a transfer function that is neither flat nor 1/f (see attachment for David's measurements of this from Caltech — driver and laser should be identical to ours). We probably want to think carefully about pole placement here. Using 𝜈FSR = 2.9 GHz and finesse of 370 implies an optical pole at 𝜈HWHM = 3.9 MHz, which is currently irrelevant but could shift down by an order of magnitude if we redo the coupling with a larger gap.
We applied 49 MHz PDH sidebands with a fiber phase EOM that Melissa lent us (LNY10D2A 200 MHz X-cut). We are detecting in reflection with a New Focus 1811. The PDH error signal is not clean because (to give one reason at least) we are desperately in need of better mode matching. In transmission, the second-order HOMs are about 50% in height compared to TEM00.
Swadha, Evan
We continued to study the transverse modes of the cavity. We attempted better mode matching with a different lens arrangement but were only able to achieve a transmitted power of TEM02 = 96 mV and TEM20 = 112 mV versus TEM00 = 270 mV (dark noise: 18 mV), which is modestly better than before but not spectacular.
We were driving the laser current with a triangle sweep at a rate of 1 V / 4.2 ms. We applied phase sidebands at 49.2 MHz and found they appeared around the carrier at ±3.05 ms, enabling a calibration of the sweep time into frequency. The TEM00 FWHM was 3.24 ms, implying a FWHM of 52 MHz, and hence a finesse of 57 (s polarization). The laser current knobs were set at 6′00″ coarse and 7′30″ fine; temperature readback 7.27 kΩ.
Similarly, the TEM02 mode appears offset from TEM00 by 10.2 ms ( = 164 MHz) and the TEM20 mode appears offset by 13.4 ms ( = 216 MHz). The mode identifications were confirmed with the camera in transmission.
We loosened the setscrew pressing the transmission prism against the cavity, the finesse rose. The transmitted TEM00 power was now 205 mV with a FWHM time of 2.52 ms ( = 40 MHz) or finesse 72. Re-tightening the screw lowered the finesse again.