We did a series of scans at different distances of the thermophile from frosti. Test 1- March 12th With the ZnSe lens Power supply Hylec (Drever and weiss) 20V ,1.448 A and 28.9W Agilent (Barish and Thorne) 19.98V, 1.463 A Drever and Weiss get warmer than Barish and Thorne. Though there is no apparent asymmetry in the thermophile scans. Total Ohmic power= 20*1.448+19.98*1.463= 58.19W The total power captured by the thermophile is calculated as follows. P(mW)= The power recorded by the thermophile A=10*10 mm^2 (Area of thermophile) The scan step size= 6mm The total power =sum( P*10^(-3)/(A*d*d)) Test 2- March 13th Without the ZnSe lens The scans look asymmetric (The thermophile was likely angled- Will retake the data) In order to reduce the disparity among top and bottom half, the power supplies were set to different values Power supply Hylec (Drever and weiss) 17.00 V ,1.232 A Agilent (Barish and Thorne) 19.98V, 1.465A Total Ohmic power= 50.2147 W The results are attached.