Reports until 16:28, Friday 21 November 2025
GRAVITES General
begum - posted 16:28, Friday 21 November 2025 - last comment - 11:40, Monday 24 November 2025(12101)
GRAVITES short MZI (2-floor input/output segments) test Part I, PZT drift fixed

[Dorotea, Begum, Eric]

A short MZI using the input and output segments prepared for the 2-floor experiment was set-up, using 2 backup AOMs and the 18m fiber on the pzt-stretcher. Some components were re-purposed from the rotating setup: pzt stretcher, 1545 and 1550 nm balanced HD boards. The short MZI lives on the optical table, within the enclosure box. This report is with the imbalanced MZI configuration, with ~20 m long fiber segment on the PZT stretcher (~18 m of it is wound on the stretcher itself, ~2 m free) which is not compensated on the other arm.

PZT drift issue:
Just like the previous setups with 1 km and 27 km long fibers, initially the the MZI would lock, the pzt strecher would drift until it rails, relock slightly above the rail, proceed drifting, rail, repeat. The PZT range was measured to be ~2.2 cm. So it became apparent that something was wrong with the setup. It turns out the IFR Marconi Signal Generator (this is the one that gets the external modulation from the MZI servo AOM control pathway) was not clocked to the SRS SG380 (Rb frequency reference). This caused a ~17 Hz frequency difference between the two RF sources that drive the two AOMs on the arms. This setting is not visible on the screen, so one should check the clock if something fishy happens with the PZT drift again. The setting can be found in Utility Group Menu --> Frequency/Sweep Menu --> (4) Frequnecy Standard. After Eric figured out this issue and corrected it, the PZT drift is completely gone! The lock point is steady at ~5.5 V at PZT MON. The MZI servo now seems to stay locked for days. 

2nd MZI Servo Box for the 2-floor setup:
MZI Servo Box is comprised of three PCBs: power board, (common) servo board, split servo board. See my log 12036 for previous work done on these. Once the second servo box is operational, a noise measurement with the two interferometer configuration will be conducted, keeping both MZIs locked with their corresponding servo boxes simultaneously with the 1545 nm fields, then measure the differential noise on 1550 nm, specifically looking for additonal noise on the unsecured segments. 

Loop characterization, MZI 2, Arms 1 & 3:
OLTF for common loop and the cross-over point of the nested loops are shown here, consistent with previous measurements. For this measurement, the control AOM and the pzt stretcher on the common arm, which is a different configuration than what is planned for the Vienna 2-floor steup. 

PZT range measurement:
I measured the range of the PZT by driving it thorugh the excitation input of the split servo board. Oscilloscope screen with 1 Hz pzt drive with 5 Vpp is shown, yellow is the 1545 nm HD signal, purple is 1550 nm HD signal and blue is the PZT Mon, showing 2pi calibration for the HD signals, and pzt voltage range that causes 3 periods of path length (+stress induced refractive index) change. The full range of the PZT is 2.2 cm, assuming all change is in fiber length.

Preliminary noise measurements, MZI2, Arms 1&3:
After leaving the box closed over the weekend, I measured spectra for the 1545 nm HD signal (also the error signal) and the 1550 nm HD signal, see attached plot. Also attached is a plot comparing the spectra measured with the 27 km long arms mounted on the rotating stage, note while the 2025-04-24 data did not have any unsecured fiber lengths associated with it, the current setup does due to the unshared pathways for the 1545 nm control signal and the 1550 nm signal-under-test. The differential noise measurement for the two MZIs will let us characterize the noise due to the unsecured segment. Full comparison will be done when the full system is operational, also plotting the SR785 and HD board noise floors for comparable Vpp. 

Images attached to this report
Comments related to this report
begum - 11:40, Monday 24 November 2025 (12113)

The attachments for the open loop transfer function for the common loop and the cross-over frequency were missing. Here they are. 

Images attached to this comment