Displaying report 1-1 of 1.
Reports until 09:42, Tuesday 02 September 2025
SQZ Site VOPO
eoelker - posted 09:42, Tuesday 02 September 2025 (12049)
H1 Spare VOPO crystal scan

[Maryrose, Eric]

On Friday, we scanned across all the co-resonance positions of the crystal to check the escape efficiency and cavity alignment at each position.  We saw no evidence of misalignment from translating the crystal and the escape efficiency was roughly equal at all 9 usable co-resonance positions.  The tenth position (-700 in the table) was too close to the edge and was not usable.  This suggests that the crystal is very well aligned and 1064 nm losses in the crystal are fairly low everywhere.

We did, however, see some slight decrease in the nonlinear gain across the crystal when keeping a constant temperature of 35.25C.  At the final position (-8700), we locked the cavity and measured an NLG of 7 with 1.33 mW in the TEM00 mode for 532 nm.  This corresponds to a threshold power of about 3.2 mW.  At the first good position (-1560) the same measurement yielded an NLG of 4.5 and threshold power of 4.5 mW.  This may simply mean that the phase matching temperature across the crystal isn't quite uniform, since we optimized our phase matching temperature near the final position.  From past conversations with vendors, my understanding is that some index variation across the crystal is common in PPLN.  Perhaps PPKTP is similar.  A very rough NLG scan where we measured the amplification in the seed power while sweeping through resonance was done on all 10 positions.  This showed a roughly linear decrease in NLG as we stepped through the intermediate points.  

This isn't particularly concerning, as these threshold values are much lower than what we've seen with previous crystals.  This cavity is operating quite efficently since we believe that the 532 nm losses are quite low (a more precise measurement of this is on our checklist for this week).

Some numbers for the escape efficiency measurement:  The crystal edges (no more cavity flashes) were at 0 and -9200 counts on the tranlation stage (the offset here is arbitrary since this stage has no position sensor).  All voltage numbers here correspond to the trans and refl PDs for the front seed path.  

Position TEM00 trans (V) TEM01 Trans (V) TEM02 Trans (V) Refl On Resonance Refl Off Resonance Esc Efficiency
-700           Not usable
-1560 3.96 0 0.110 1.67 1.82 97.9%
-2460 3.92 0 0.110 1.67 1.82 97.9%
-3400 3.96 0 0.110 1.67 1.82 97.9%
-4300 3.96 0 0.110 1.67 1.82 97.9%
-5100 3.96 0 0.110 1.67 1.82 97.9%
-6000 3.92 0 0.112 1.67 1.82 97.9%
-6900 3.80 0 0.102 1.66 1.80 98.0%
-7800 3.86 0 0.108 1.66 1.80 98.0%
-8700 3.80 0 0.100 1.66 1.80 98.0%

 

Relevant formulas (position -1560 shown as an example):

Mode matching:  3.96/(3.96 + 0.110) = .973

Reflection Dip:  1.67/1.82 = .918

Solving for intracavity loss from reflection dip and mode mismatch:   0.918 = 0.973*(sqrt(R1) - sqrt(Rloss*R2))^2/(1-sqrt(R1*R2*Rloss))^2  + (1-0.973)

assuming R1 = 0.93,  R2 = 0.999, we get that Rloss = .9994.  This corresponds to 600 ppm of excess intracavity loss.  

Escape Efficiency:  0.979 = (1-.93)/(1-.93*.999*.9994)

 

Displaying report 1-1 of 1.