This week I spliced all the components for the input to the 2fl measurement, put them in an enclosure, and tested the loss. I didn't prioritize keeping the fibers as short in order to leave room for redoing parts of the setup. A diagram of components is attached; note that the 1st switch (which switches between CW/photon source, and would be located before the '1550 in' line on the diagram) is not shown in since that component is being tested in Vienna-- we eventually will want to add that switch to this assembly, and I lean towards using the CrystaLatch switches that we have here, since we can run multiple off of one function generator to keep everything well synced. Currently I just have all the components laid out between pieces of acoustic foam and shoved into the box-- if we need better isolation than this we can add more insulation to the outside. I haven't set up any kind of temperature control yet but plan to just stick an omega pad on top of the box, put a thermistor inside, and wrap the whole thing in thermal insulation. I also redesigned my optical switch drivers in a split configuration so that the majority of the circuit (especially the voltage converter) can stay outside of the box and the signal just goes in to the box and connects to the switch through an sma cable.
Begum and I tested the loss for both wavelengths on each output (results are shown in an attached image). Note that the loss looks higher for the 1542 because of the 50/25/25 beamsplitter being used. In actuality the loss is the worst on the channels with the switch. The switches seem to have around half a dB of input loss. Each channel has at most 1.1dB of total loss between the input and output (with the 'outputs' here being where the light would enter the arms).
Next steps are to assemble the output arm and new switch drivers and finish getting our servo working-- once that's done Begum and I will test the whole system to see how long we can stay locked with these sections of unsecured fiber.