I did a temp scan with the H1 Spare VOPO today to further optimise the NLG. Turns out that my starting value was already pretty much right on (35.25C)
Input green power 1.7mW. Seed w/o amplification 320 mV. At each temp i moved the stage a bit to recover co-resonance. I'm at one of the middle co-resonances at the moment. FWHM for phase matching appears to be about 4C, which is roughly consistant with my recollection for this length of PPKTP crystal.
| Temp | Delta V | NLG |
|---|---|---|
| 32.25 | 0.624 | 1.95 |
| 33.25 | 0.912 | 2.85 |
| 34.25 | 1.36 | 4.3 |
| 35.25 | 1.84 | 5.75 |
| 36.25 | 1.38 | 4.3 |
| 37.35 | 0.872 | 2.72 |
| 38.25 | .628 | 1.97 |
At the peak phase matching, this corresponds to an incident power of about 5.1 mW for 532 nm at threshold. Since I only have about 80% mode matching, this means that my threshold power is 4 mW for TEM00. This agrees with my estimation at a much higher nonlinear gain on friday (3.4 mW incident, nlg =29.5).