Calibration of frequency modulation:
- idea: ramp PZT and use fiber MZI to track frequency change
- fiber MZI has 30MHz FSR
- set analog remote control gain of CTL to 5V/V; modulate with 1Vpp + offset to not rail input or PZT
- -> 40 fringes for 0.91V change on PZT modulation input = 1.32 GHz/V
- change ARC gain to 10V/V, modulate at 5Vpp -> 13.2GHz peak-to-peak modulation of 1560nm field (corresponds to about 0.1nm pp)
- also: offset CTL wavelength to compensate for DC frequency offset to maximize DC output of SHG: optimum at 1560.05nm
Test after SHG:
- send beam to PD after dichroic BS before coupling to chip to test if any power modulation is visible due to SHG linewidth
- some modulation coherent with frequency ramp is visible:
- as expected power is maximal at center of ramp; at max and min voltage power drops (symmetrically) to 92.9% of maximal value
- -> some shape visible, but still well within linewidth of SHG
Test with waveguides:
- coupled to widest (and shortest) loop with Mitotoyo objective and put light on PD
- saw same shape with ramp from linewidth of SHG, but also smaller fringes with much smaller period
- did not see those small fringes with lens coupling to waveguide instead of objective, so maybe come from parasitic cavity in objective?
- for this waveguide any Fabry Perot effect seems negligible
Other remarks:
- when testing transmission through objective I saw that the transmitted power is very sensitive to the objective horizontal and vertical translation, which points to clipping on the input aperture
- result with lens looked promising, however, beam too far from center, which seems to distort beam
- beam path not straight anywhere, so I decided to put the microscope assembly on the breadboard and straighten out the beam