TIR cavity with 2.5 µm foil

Swadha, Evan

We continued coupling studies with the fused silica cavity and prisms, this time using 2.5 µm aluminum foil applied using the procedures described previously.

Swadha has set up the cavity in the vacuum tank for signal injection and extraction.

The following describes the optical configuration when the cavity is resonating, with powers given by a power meter. The laser is an NPRO (1064 nm) and the input polarization is p.

The cavity finesse in p is something like 700, and the finesse in s is higher. I did not make a more detailed measurement yet than eyeballing on the oscilloscope.

Now, some comments about mode matching and HOMs:

I turned the input power down to 1.84(5) mW, giving 1.32(5) mW in reflection. I set up an NF1811 in reflection and found the following:

Non-image files attached to this report
Comments related to this report
evanhall - 11:42, Tuesday 10 June 2025 (11980)

The attached notebook (augmented from an earlier one) computes the tranverse mode spacing in the vicinity of the carrier as the effective ROC is varied. There could also be some effect from the path length variations due to the slightly non-square path length traversed through the bulk of the cavity, but this is not considered.

When the cavity is locked in s, we see both TEM(0,22) and, more faintly, TEM(12,5), on the transmission camera. Other predicted modes are not obviously visible.