GRAVITES General
haocun - posted 00:54, Saturday 22 March 2025 (11920)
Interferometer remains locked during rotation

We have populated all the fiber components of the interferometer onto two 8"x8" breadboards and mounted them around the pivot of the rotating stage (see attached photos). The rotation is reasonably smooth, and the interferometer stays locked during motion (see attached video). Some transient peaks were observed at the end of motion due to deceleration. As expected, the PZT drifts faster during rotation than when it's stationary, which brings up the need for temperature control in the next step. Haven’t seen issues from polarization changes so far, but we’ll add polarization control components going forward. I plan to test rotations beyond 90 degrees after tidying up and securing all fibers and cables better.

[Homodyne for 1550 nm] Eric and I tried to fix the issue of the homodyne detector for 1550 nm. One of the photodiodes on the board gave excessive noise when we touched or jiggled it. We replaced it with a new diode yesterday, but it appears that today the other diode is also failing to detect the signal light. We probably need to buy additional diodes to fix it.

Images attached to this report