Reports until 21:55, Friday 31 January 2025
GRAVITES General
Haocun - posted 21:55, Friday 31 January 2025 (11882)
Photon interference with temperature tuning [Vienna]

By gradually tuning the temperature of one of the 50 km fiber spools, I was able to get the zero arm length difference within the photon coherence length (around 3 mm, corresponding to a 3–5 mK temperature range). This allowed for initial benchmark measurements of photon phase noise at low frequency with interferometer locked.

I injected HH photon pairs into one input of the MZI before the first BS. With a 50% probability, the photons separated, each traveling along an arm of the interferometer before rebunching at the second BS. This resulted in single-channel counts [prop to 2sin4(phi/2), 2cos4(phi/2)] and coincidence counts [prop to sin2(phi)] that varied with phase fluctuations. (This setup is different from the final measurement scheme planned; it was chosen for convenience to take an initial measurement using the current MZI setup, without a PBS or polarization control.)

 

Images attached to this report