Swadha, Sasha, Matt, Evan
We have begun studies of FTIR coupling between right-angle prisms using kinematic mounts. We are using Edmund Optics prism #47-785, Corning 7980, 20 mm height, uncoated.
We started with copper leaf from Barnabas gold. We folded a square of this leaf on itself to create 16 layers on top of each other and measured with a highly accurate micrometer to have thickness 10(2) µm. This implies a thickness of the single layer 630(130) nm.
Swadha cut the copper leaf into strips with a razor blade and placed them on the face of one of the prisms (they stick electrostatically). We then use a 5-axis translation stage to press one prism against the other, sandwiching the strips. Using the translation stage screws by themselves does not give sufficient compression. We had to press the stage by hand, and then we achieved the following coupling: on a PDA10CS in reflection, 2.8 V of power; on a PDA20CS in transmission with 60 dB of gain, 220 mV of power, implying a power transmission of 80 ppm in the p polarization. Repeating with the s polarization: 2.9 V in reflection, 125 mV in transmission, implying 45 ppm of transmission in the s polarization.
For glass we would expect that a gap of <1 µm would give transmissions exceeding 0.1, so this would imply we are not reaching a gap consistent with the thickness of the leaf. However, inferring the gap size is difficult because it is exceedingly sensitive to the value of the index of refraction, and to a lesser extent the angle of incidence.