I've been working to install the feed forward filters on the ISI (Stage 0 L4Cs -> Actuators). At the sites Jim has these working around 10Hz (maybe 3-30Hz? need to double check).
This is done by measuring the L4C to GS13 TF and the Actuator to GS13 TF, and then fitting the ratio (GS13/L4C)/(GS13/ACT_ = ACT/L4C
The ZFeedForward plot shows three different filters and their predicted performance (Suppression), the blue line is the data (fitting Goal), so you can see that the amplitudes are pretty good from ~1 to 20Hz, phases are mediocre.
The first two (green and olive) which map to Blue and green in performance, sorry about that, I did myself. The third (red and olive) was done using a fitting tool that Nikhil has written.
On the second plot you can see the results of the first filter which pretty much does just what is predicted