ISI stabilisation with C-6D
ISI was stabilised relative to C6D in RX, RY, RZ with a blend at 25 mHz and X, Y loops with a blend of 35 mHz. Z was stabilised with GS-13 because C6D's Z mode is stiff. The RX,RY,RZ blending frequency was a bit higher than the design one (8 mHz) because of the actuation noise from the RZ offset and RX/RY degeneracy.

As discussed in log 11846, our stock was welded at a significant angle (~0.15-0.2 rad) relative to the vertical axis. I thought that it would be straightforward to correct the asymmetry digitally. However, it turns out it is a bit complex. Our general strategy is to run 6D controls in its own coordinate system that is aligned to the eigen rotation axes of the fibre. At Lasti, we need to stay aligned with the ISI coordinates and need to rotate C6D's eigen axes. This is tricky because the frequency response of RX and RY are different. First, I tried to digitally reduce the RY eigen mode from 16 mHz down to 7 mHz (to match RX's eigen mode). However, I noticed that the ISI RY -> C6D RY response develops a notch at 16 mHz from the servo. This is probably because of the RY -> X -> RY coupling and requires further investigation.

Then, I decided to do our usual feedforward of X, Y to RY, RX and add another digital filter to make RY's response similar to RX's response to the ISI tilt. This approach worked well above 7 mHz but the transfer functions are not well understood at lower frequencies yet. I think the lesson learnt is that we should disregard any fibre with angled stocks relative to the vertical axis in the future.

The first attached figure 'RXYZ_blend' shows the blending filters for RX,RY, and RZ. I think it can be further improved and my initial goal was to achieve an order of magnitude isolation at 0.1 Hz. From the noise figures discussed in log 11848, we may potentially blend angular degrees of freedom at 15 mHz. However, since I was not quite convinced of my frequency dependent rotation of the C6D coordinates, I blended angular modes at a higher frequency.

The second attached figure 'XY_blend' shows the blending filters for X and Y. Since tilt is suppressed only above 25 mHz, I decided to blend at 35 mHz with the goal to achieve an order of magnitude noise suppression around microseism.

I have also found that C6D's bandwidth is limited by the 18 Hz mechanical mode. It likely comes from the LPS posts. I have, therefore, blended C6D with GS13 signals above 2 Hz to maintain the original bandwidth of the ISI control loops.

The last four figures show the performance of the C6D isolation. Figures 'X_noise' and 'Y_noise' are quite similar. However, the Y-blend is clearly a bit more marginal than X-blend and requires further tuning. Also, I add a red dashed curve that I measured for the ISI isolation with GS-13. This was measured in log 11848 and the blends are as Rich left them before the break: 250 mHz for RX/RY/RZ and 100 mHz for X, and Y. In the future, it would be interesting to look at the out-of-loop T240 sensor.

Figure 'RX_noise' and 'RZ_noise' show  the isolation of the RX and RZ degree of freedom with C6D. Interestingly, the RZ isolation does not show an order of magnitude improvement at 0.1 Hz relative to the uncontrolled state. I think this is likely because ISI X and Y actuation excited RZ by an order or magnitude around microseism and then this extra motion was suppressed by the RZ loop.

Also, it is important to note that LPS run without frequency stabilisation servo because we are missing a temperature controller for our DFB laser. Rich and I borrowed one from the green lab and I guess it was recently claimed back. It does not seem that the LPS frequency noise was a problem in these measurements though because Z degree of freedom was still below all other signals below 5 Hz.