denis.martynov - posted 06:37, Wednesday 25 December 2024 (11847)
C-6D low-noise transition
Rich, Den

Last night, Rich and I have partially transitioned C-6D to the low-noise state. We could not go all the way due to the RZ offset. "Low-noise" means actuators in the low range. In air, we operate in the high range and high noise regime with zero impedance of the HAM A coil drivers that control C-6D. This is required to provide enough force (max of 150 uN per coil) to keep the inertial mass controlled in the presence of air currents and during the pump down.

In the low-noise state, we reduce the actuator range and utilise HAM A coil drivers with a bandstop filter that suppresses the DAC noise at 1 - 500 mHz. Before starting the switching procedure, we should, ideally, have all C-6D control signals equal to zero. Otherwise, transients from the switching process may imbalance the mass. We can rebalance RX/RY with magnetobullets as will be discussed below. However, there is no way to rotate RZ remotely in the current design. In Birmingham, we used to vent the tank and manually rotate the top rotation stage. Once done once, the mass comes back to the nominal position after the following pump downs. However, in Lasti, venting is a much more complex and time consuming process. Therefore, we should install a rotation stage with remote control in the future.

Step 1: RX/RY rebalancing. There is one magnetobullet per arm as shown on the attached scheme. In total, there are six Peek coils to move three magnetobullets because each coil can only push. There is only one CDS channel that controls the coils. A particular coil can be selected using the magnetogun switchbox (located inside the 19'' rack). It has 7 positions: 0 means that none of the coils is connected and numbers 1-6 correspond to a particular coil. Each bullet moves perpendicular to its arm. To select the proper coil, we first looked at the control signals V1-3. Positive control signal on a particular vertical coil means that the arm is too high and the coil tries to push it down. Therefore, move mass needs to be moved towards the arm. For example, if V1 = 0 cnts, V2 = 200 cnts, V3 = -200 cnts (all signals add up to zero) then we need to select coil 1 because it will move bullet 1 towards arm 2 and away from arm 3. 

The magnetogun block is embedded into the main C-6D medm screen. Only the bottom row of the two is utilised and the top row is kept as spare. There are 3 fields (cycles, amplitude, frequency) and one command (BANG!). The only parameter that needs to be tuned is "Cycles" that determines the duration of the pulse to a particular magnetogun (Peek coil). The default value is 30 cycles (30 / 16384 = 1.8 msec) that means that a sin wave of max DAC amplitude (set to 33,000 cnts) and frequency of 3800 Hz is transmitted to the coil. The frequency of 3.8 kH is determined by the resonance of the LC-circuit that powers the guns. A pulse of duration of 30 cycles changes the control signal in the vertical coils by ~30 cnts. Note that the movement of the bullet is quadratic with the duraction of the pulse and a 100 cycle pulse would move the bullet ~10 times more than a 30 cycle pulse.

Step 2: once all vertical coil signals are nulled (smaller than 30 cnts), we replaced high-range HAM A drivers with the ones with bandstop filters. In the current design, bandstop filters are not switchable and we just reconnected the cables. In principle, both coil drivers can be reconnected simulteniously and, meanwhile, the mass can float uncontrolled. However, since we have a significant RZ offset, we controlled RZ with coils H2 and H3 (connected to the second HAM A driver) and replaced the first driver (that controls V1-3, H1). We have then engaged filters in the medm coil filter banks to compensate for the bandstop filters and engaged RX/RY control loops. We have then transitioned the RZ control signal to H1 and replaced the second HAM A driver.

Step 3: increased the output impedance of the HAM A coil drivers. The internal output impedance of our HAM A drivers is zero Ohm. There is a separate switchbox that allows to select output impedance of 0 Ohm, 500 Ohm, 1 kOhm, etc. Note that this value means impedance per path (both input and return). For example, if 500 Ohm is selected, this means that the range (and noise) of the driver is reduced by (2 * 500 + 43) / 43 = 24.25 where 43 Ohm is the coil impedance. We have switched all vertical coils to the 500 Ohm state and compensated for the lost gain in MEDM.

Switching the horizontal coils is a bit harder, again, due to the RZ offset. It would not be possible to transition coils H1-3 to the 500 Ohm state. The second HAM A driver that controls H2-3 and magnetoguns is connected to a separate switchbox with two states: 0 Ohm and 150 Ohm (for channels H2-3). This impedance reduced the HAM A noise and range by a factor of (2 * 150 + 43) / 43 = 8 compared to the zero impedance state. We did not have time to modify the impedance of H1 and its lowest value (after 0 Ohm) is still 500 Ohm. We tried to transition H1 to the 500 Ohm state but the control signal would not have enough range to suppress the transition transient. We put the coil back to the 0 Ohm state for now.