Reports until 19:02, Wednesday 06 November 2024
GRAVITES Electronics
eoelker - posted 19:02, Wednesday 06 November 2024 (11823)
Performance measurements for new fiber stretcher

[Dorotea, Eric]

We recieved our new fiber stretcher late last week.  On monday, we wound the stretcher with 6 turns of PM1550 fiber.  Hopefully using PM fiber will minimize cross talk between phase actuation and polarization.  Given the cylinder diameter (70 mm) this corresponds to about 1.5 meters worth of fiber and given the unloaded circumferential expansion (420 um for 150V applied) we were anticipating that we'd get about 2.4 mm of total strech.  However, when we hooked this up to our interferometer and counted fringes, we seem to be measuring closer to 0.9 mm, suggesting that either the blocking force of the piezo isnt high enough to produce the desired strech with 6 windings or that we didn't wind the spool tightly enough.  I think that this should be sufficient for our first round of experiments (where the fiber coils will be stationary), but subsequent measurements with the moving stage likely will require more range. 

This evening we roughly measured the actuators loaded resonance frequency and found it to be around 900 Hz.  This is probably high enough that we can get away with only one piezo actuator and forego the additional high speed actuator for now provided that we lower the crossover frequency between the Piezo and AOM to 50-100 Hz or so.  I will reconfigure the servo parameters tomorrow to give this a shot. 

One thing to note about this actuator: It has a relatively large PZT capacitance of ~4.5 uF.  Not surprising given how massive it is, but somehow this slipped our mind when we were first setting things up.  After observing some aggressive low-passing behavior, we measured the junction capacitance and discovered the cause.