Yesteday, I managed to dither lock the OPO on the CLF.
Description: The current configuration of the loop consists in the following [1]:
1/ CLF enters the OPO from the high reflectivity mirror (henceforth called input mirror).
2/ Dither drive sent to the low-reflectivity OPO mirror (henceforth called end mirror, as seen from the CLF's path) [2].
3/ Error signal read on REFL by demodulating at the dither frequency [3].
4/ Loop closed by actuating on the OPO's end mirror.
Here are the details for each part:
1/ I can send max ~150mW of CLF arriving in the setup. Note that 50% of it is instantly dumped into a compact PD due to the BS having at 50/50 ratio.
2/ See screenshot here for the setting of the IQ module. I send 0.02V amplitude at 5kHz from the RP at its output 2; since it's amplified by x100 the end mirror effectively is dithered at 2V amplitude.
3/ Because the cavity is very undercoupled, most of the power impinging on the REFL PD is a DC signal. However the RP's input saturates at 1V. Thus I had to make and add a 100Hz highpass on the cabling from the REFL PD to the RP, so that only the interesting, non saturating 5kHz error signal is fed into the RP. It is a simple RC filter with R = 10kOhm and C = 0.15uF as seen here. See screenshot here of the SR for a spectrum of this block that I took on the SR785 [4].
4/ See screenshot here for the shape of the error signal [3]. See screenshot here of the loop OLTF. It has a UGF of 700Hz and good phase margin. In practice it is very stable as I can tap on the OPO cavity without breaking lock.
Conclusion of this work: There is 250uW of stable CLF going out of the cSQZ and into the HD for alignment.
Appendix: Some subtleties/tips that I encountered:
[1] In the mirror dither lock configuration, the RP only needs one input ("in2") to read the REFL error signal, and one input ("out2") to both dither the end mirror and send the correction signal to it (so both signals are overlapped in this channel). This is different from the laser dither configuration, where one output is used to send the dither signal to the laser head and another one is used to send the correction signal to the end mirror. This is important and has implications which channel should be acquired for the error signal fit and lock, as described in the following points.
[2] I tried to send the dither on the laser head and lock on the REFL, but with no success. The main offense was the DC offset on the demodulated error signal as reported in the previous log here. The hypothesis was that it comes from some FM-to-AM coupling when dithering the laser head. To test this, I sent a sine dither at 1V amplitude at 80kHz arriving on the fast port of the laser dither and I measured the power spectrum of the laser on a PD. The DC voltage measured by the PD is 880mV. I obtained the plot here on the Agilent, where -34dBm converts to 4.2mV, thus a RIN of 0.5%. This is manifestly too much for obtaining a non-offsetted demodulated error signal.
Note that the DC offset does not appear when I dither the OPO end mirror insted of the laser, because only the light which enters the cavity gets modulated.
[3] A lot of problems I encountered yesterday on the error signal plots aquired by the RP are caused by a bad choice of channels to be aquired and bad filtering of the demodulated signal. I recall what module should send what and what should be acquired:
- The dither is generated by the IQ0 module and directly sent to 'out2'.
- The scan ramp is generated by the 'asg0' module. It is diectly sent to 'out2' thus overlapped with the dither.
- 'out2' is plugged to some x100 amplification and then sent to the end mirror.
- 'in2' is plugged to the REFL PD output after the RC block. It thus only contains the modulated error signal. It is passed into the IQ0 module for demodulation. The demodulated error signal is 'iq0'.
- To plot a error signal scan, we should in theory plot 'iq0' as a function of 'out2'. However, if we do this we obtain some nasty plots (see here and here (zoomed) for examples of demodulated error signal which still contain some extra modulation). The explanation: in practice I notice that 'iq0' still has some spurious modulation . Thus 'iq0' is sent to the PID0 block which acts as a lowpass filter with cutoff frequency chosen at 0.1x the dither frequency (500Hz in our case). The lowpassed error signal corresponds to 'pid0'. Furthermore, recall 'out2' has both the scan ramp and the dither. So it is cleaner to only take the scan ramp. Thus the correct error signal scan plot corresponds to "pid0" plotted vs "asg0". Doing so allows the fit to work.
[4] It is important to recall that the SR785 has a 1MOhm input impedence while the Agilent has a 50Ohm input impedence. This means that for low frequency measurements, with filters whose impedence is much larger than 50Ohm, like the RC filter I made, the Agilent will not give the correct TF. The RP's inputs are 1MOhm so they reflect the measurments on the SR785.