I received and spliced a 100m and a 200m SM28-ultra fibers from corning. The losses displaced on the splicer are 0.00dB for both of them. NB: when you splice be careful to make the fiber holder 250 touch the blue holders.
I characterized the losses using both the NKT and the Thorlabs laser (to double check due to laser amplitude noise/fluctuations).
NKT - 100 meters
P(before) = 54uW
P(after) = 52.8uW
Loss = 2.2% - Loss_dB = 0.098 dB
Thorlabs - 100 meters
P(before) = 180uW
P(after) = 174uW
Loss = 3.3% - Loss_dB = 0.15 dB
NKT - 200 meters
P(before) = 54uW
P(after) = 48.5uW
Loss = 10% - Loss_dB = 0.47 dB
Thorlabs - 200 meters
P(before) = 180uW
P(after) = 154uW
Loss = 14% - Loss_dB = 0.68 dB
These losses are way higher than expected.
I inserted the spools into small boxes I found in Rai's office as shown in the attached photos.