We want to control the relative phase-angle between the two squeezed beams on the first beamsplitter using a 1% pickoff after this beamsplitter. The expected power levels in the CLF beams are as follows: Compact Squeezer OPO: Rin-out = 0.89 Rclf = 0.9995 Ptrans/Pinc = 0.017 So if we send in a 1 mW CLF beam, we will have 170 nW of CLF power after the 1% pickoff. Breadboard Squeezer OPO: Rin-out = 0.845 Rclf = 0.9996 Ptrans/Pinc = 0.01 So if we send in a 1 mW CLF beam, we will have 100 nW of CLF power after the 1% pickoff. If we use a Newport 1811 RFPD, which has about 8 pW/sqrt(Hz), with a 100 kHz demodulation bandwidth, we expect to have a noise-equivalent-power of about 2.5 nW. As a result, we should be able to achieve a reasonable SNR by directly detecting the CLF beams with a low-noise RFPD. If we instead use a beamsplitter with a several mW LO and a pair of photodetectors, we should be able to increase the SNR further at the cost of added complexity in the setup.