Reports until 20:13, Thursday 05 October 2023
GRAVITES General
epolini - posted 20:13, Thursday 05 October 2023 (11357)
OLTF of the unbalanced MZI

[Eleonora, Wen]

Yesterday, we acquired the OLTF of the unbalanced MZI with the SR785 to characterize the loop. 

We inject a sweep sine from 100 Hz to 10 kHz and we measured the TF in different configurations:

Before lunch

After lunch

Something that can be noticed is that the noise amplitude, needed to perform this measurement, incresed between before and after lunch. It can be due to a change of the demodulation phase, since it is not controlled. This is not the case unlocking and re-locking the loop. The TF shape did not change. 

 

 

Images attached to this report