[Anders, Dorotea]
Two weeks ago, Dorotea and I measured-out and cut 2 roughly 7.5 meter jacket-free fiber cables to use as arms for preliminary testing of the linear vertical actuator for the GRAVITES 1064nm ifo prototype.
This week and last, I succesfully connectorized the 2 fibers.
For future reference, I used Jonard Tools JIC-375 fiber strippers and methanol to strip-free and clean the fiber core from the cladding. I then attached 4 Thorlabs connectors using EPO-TEK 302-3M epoxy with a Thorlabs 3 cc syringe and needle. I then let the epoxy to cure over the weekend. This epoxy is recommned to cure for 3h at 65ºC for curing, but also cures "sub-optiminally" in 24h at 23ºC. Since I applied the epoxy Friday, I assumed that leaving it over the weekend would definetly allow it fully cure, and that an "optimal" cure was not neccesary. I then used a Thorlabs scribe, and a 30um Thorlabs lapping sheet to cut off the tip of the fiber and delicately shave off the excess epoxy. For the fiber polishing process, I used M.4423.1 5um, M.4432.1 1um and M.4450.1 Ultrafilm B ULTRA TEC polishing films with a ULTRA TEC polisher. I also used a Thorlabs fiber inspection scope during the polishing process to verify that the glass wasn't broken and that the polishing was working.
For reference, I followed the general procedure outlined in the 3M_Connectorizing_Tutorial.
I also measured the power losses of the cables using the RIO laser, finding that one of the arms had a ~9% power loss and the other ~20%. The RIO laser output was measured to be 1.045 mW, and the outputs of the arms were 0.951mW and 0.833 mW respectively. Using the fiber inspection scope, I identified one of the fiber tips that appeared imperfectly polishied. My assumption at this point is that this is the cause of the larger coupling loss.
The plan is to repolish the identified tip and then leave it for Dorotea's return.